Products

— 产品中心 —

Lightning indirect effect test system

To simulate aircraft might suffer lightning or for the damage caused by the internal electronics, DO160section22 part gives the detailed test method, this system fully meet RTCA DO - 160 - g version of the standard, can be used to lightning transient induction test, airborne equipment can meet the test of airbus, Boeing and other airlines requirements, at the same time can meet the latest GJB 8848 lightning conduction coupled injection test. In addition, in order to save the test cost, developed a special can meet DO160 level 4 of the following tests (can meet more than 95% of the daily testing tasks) of equipment, at the same time compatible with the latest edition of the MIL - STD - 461 - g CS117 lightning military equipment cable transmission caused by sensitivity test, the device adopts the design of more integrated, only need a cabinet to complete a single response experiment and back many times, greatly saving the configuration time. This system can be widely used in the lightning indirect effect transient induction test of electronic systems of aerospace, aviation, vehicles, ships and various military equipment, and can also be used in other related research and experiments.

Damage effect on aircraft structures and other parts.

Standard

SAE ARP5412  Aircraft Lightning Environment And Related Test Waveforms
SAE ARP5415 User.s Manual for Certification of Aircraft Electrical/Electronic Systems for the Indirect Effects of Lightning
RTCA/DO-160F/G  Environmental Conditions and Test Procedures for Airborne Equipment Section 23
Lightning Direct Effects
MIL-STD-461G CS117  conducted susceptibility, lightning induced transients, cables and power leads
GJB 8848-2016系统电磁环境效应试验方法
top.jpg

Characteristic

Multiple configuration schemes to meet the needs of different users
One machine can achieve multiple waveforms and various testing functions
FSG-160MS USES 2 hosts to complete output of 8 waveforms of 6 classes
The single FSG-117MS generator can satisfy both Internal and External Equipment of the military CS117
Test requirements, which can meet the test requirements below grade 4 of DO160
Can meet GJB8848 short pulse, medium width pulse and long pulse test grade D, and provide corresponding test accessories
Single instrument can perform single return, multiple return, and multi-pulse group test function
The test voltage and interval time can be set arbitrarily, and the test process can be programmed
Using touch screen control, automatic intelligent control
Modular design structure, can be equipped with a variety of waveform modules
Various test attachments are available to provide one-stop test solution
  • FSG-160MS(W1、W4、W5)

  • FSG-160MB(W2、W3、W6)

  • Waveform selection module

FSG-160MS

FSG-117MS

The basic parameters

DO160Test level

Grade five(W1,W4,W5A,W5B)

Grade four( W1,W4,W5A,W5B)

CS117Test level

Completely satisfied

Completely satisfied

Equipment appearance

The two cabinets are connected in parallel

A single cabinet

The equipment size

35UTwo cabinets

35UOne cabinet

W1Current waveform output capability (medium width pulse)

Short circuit current waveform(μs

6.4/69

6.4/69

The source port outputs the current(A

Up to 3500A

Up to 2000A

Minimum interval time(s

20s  to 999

10s  to 999

Single return amplitude( V / A

Up to 3500A 

Up to 2000A 

Multiple return amplitude (first time/subsequent, A / A

Up to 2000A/1000A

Up to 1000A/500A

W4Waveform parameters (medium width pulse)

Open circuit voltage waveform(μs

6.4/69

6.4/69

Short circuit current waveform(μs

6.4/69

6.4/69

Source port output voltage(V

Up to 2500V

Up to 1500V

Source port output voltage(A

Up to 500A

Up to 300A

Minimum interval time(s

20s to 999

10s  to 999

Pin injection output amplitude(V / A

Up to 2500V/500A

Up to 1500V/300A

Single return amplitude( V / A

Up to 2500V 

Up to 1500V 

Multiple return amplitude (first time/subsequent, V / V

Up to 1600V/800V

Up to 900V/450V

W5AWaveform parameters (long pulse)

Open voltage waveform(μs

40/120

40/120

Short circuit current(μs

40/120

40/120

Source port output current(A

Up to 5500A

Up to 3000A

Minimum interval time(s

30s  to 999

20s  to 999

Pin injection output amplitude ( V / A

Up to   3000V/3000A

Up to   1800V/1800A

Single return amplitude( V / A

Up to 10000A  (2T:1T)

Up to 5000A  (2T:1T)

Multiple return amplitude (first time/subsequent, A / A

Up to 4000A/2000A

Up to 3000A/1500A

W5BWaveform parameters(Long pulse,optional)

Open voltage waveform(μs

50/500

50/500

s

50/500

50/500

Source port output current(A

Up to 3000A

Up to 2000A

Minimum interval time(s

50s  to 999

30s  to 999

Pin injection output amplitude( V / A

Up to   1900V/1900A

Up to   1000V/1000A

Single return amplitude( V / A

Up to 5000A  (2T:1T)

Up to 3000A  (2T:1T)

Multiple return amplitude (first time/subsequent, A / A

Up to 2000A/1000A

Up to 1000A/500A

Note: the above generator output waveform parameters can be customized according to customer requirements

Basic parameters

DO160Test level

Grade five

CS117Test level

Completely satisfied

Device appearance

A single cabinet

The equipment size

Two 5U cases can be installed in 35U cabinet

W2Voltage waveform output capacity (short pulse)

Open voltage waveform(μs

0.1/6.4

Source port output voltage(V

2000V

Minimum interval time(s

10s  to 999

Single return amplitude( V / A

Up to 2000V   

Multiple return amplitude (first time/subsequent, A / A

Up to 2000V/1000V

W3-1MHz /10MHzOscillating waveform output capability

Open voltage waveform(μs

1MHz10MHz(Damped wave)

Short circuit current waveform(μs

1MHz10MHz(Damped wave)

Source port output voltage(V

4000V

Source port output current(A

128A

Minimum interval time(s

10s  to 999

Pin injection output amplitude( V / A

Up to 4000V/128A

Single return amplitude( V / A

Up to 4000V   

Multiple return amplitude (first time/subsequent, A / A

Up to 4000V/2000V

Pulse group amplitude( V / A

Up to 3000V   

W3-1MHz /10MHzOscillating waveform output capability

Short circuit current waveform(μs

0.25/4

Source port output current(A

200A

Minimum interval time(s

10s  to 999

Pulse group amplitude( V / A

Up to 200A   

Note: the above generator output waveform parameters can be customized according to customer requirements

Waveform selection module

Waveform selection module

澳门新莆京7906not

Model:FSG-160-MOD-L1

Attenuation waveform amplitude for grade 1 and grade 2 testing,

It is suitable for W4, W5A and W5B waveforms

Mainly used for PIN injection test and cable bundle test

Need to cooperate with fsg-160 or fsg-117 generator.

澳门新莆京7906not

FSG-160-MOD-JG35

Adopt 35U standard cabinet, consistent with FSG160 and other equipment appearance

The fsb-160mb series waveform module can be conveniently stored neatly

Built-in 2 4U host storage slots

Built-in 4 standard module storage slots

Slide guide for easy placement

Solve the problem of disorderly storage of all waveform modules in laboratory.

Test the module selection

澳门新莆京7906not

FSG-160-LCT-W15

Current coupled transformers

For W1, W5A, W5B current waveform coupling

Can meet the cable bundle W1, W5A, W5B waveform single return, multiple return grades 1-5 test

Maximum coupling W1 waveform 4kA (1T: 1T)

Maximum coupling W5A waveform 10kA (2T: 1T)

Maximum coupling W5B waveform 5kA (2T:1T)

澳门新莆京7906not

FSG-160-LVT-W45

Voltage coupled transformers

For W4, W5A, W5B voltage wave coupling

Can meet the cable bundle W4, W5A voltage waveform single return, multiple return grade 1-5 test

Maximum coupling W4 voltage waveform 1600V (5T: 5T)

Maximum coupling W5A voltage waveform 1600V (7T: 7T)

Maximum coupling W5B voltage waveform 300V (10T: 10T)

澳门新莆京7906not

FSG-160-LVT-W23

High frequency voltage coupling transformer

Used for W2, W3 (1MHz, 10MHz) voltage waveform coupling

Can meet the cable bundle W2, W3 voltage waveform single return, multiple return, and multiple pulse group level 1-5 test

Maximum coupling W2 voltage waveform 2000V

Maximum coupling W3 voltage waveform 4000V

澳门新莆京7906not

FSG-160-LVT-W6

High frequency current coupling transformer

For W6 current waveform coupling

Can meet the cable beam W6 current waveform of multiple pulse group level 1-5 test

Maximum coupling W6 current waveform 160A

澳门新莆京7906not

FSG-160-CN-W45

Power coupling unit

Used for coupling W4, W5A and W5B waveforms

Maximum voltage of isolated ac/dc power supply is 400V

Ac USES pressure-sensitive couplers, containing 130V, 250V and 420V3 grades

The coupling below dc 200V is capacitively coupled, and the pressure-sensitive coupling can be used above 200V

澳门新莆京7906not

DN-416T-COM

Power supply decoupling unit

Used for decoupling and coupling of W4, W5A and W5B waveforms

Maximum voltage of ac/dc power supply: 3-phase 400V 16A, 0-800hz (common mode)

Single-phase filtering is realized by using common mode inductor and decoupling capacitance

It can satisfy the power test with W4, W5A and W5B waveforms injected by pins

澳门新莆京7906not

Lisn-4580d line impedance stable network

Used for cable bundle test to isolate radio interference and provide stable test impedance

Inductance: 5 x H (to meet LISN requirements of DO160)

The maximum voltage of ac/dc power supply is 450V 80A

Three - phase power supply power supply needs to use 4 at the same time.

CAP-33000 capacity

For use with LISN in cable bundle test

Maximum voltage of dc power supply: 400V

The capacitance is 33000uF

Measure and match accessories

1539332461(1).jpg

MDO3052

Tektronix series digital oscilloscope

Frequency: 500Mhz; sampling rate: 1.25gs /s

The storage depth is 10Mb and can be used to test multiple return strokes and pulse group waveforms

1539332468(1).jpg

P5664

Current sensor

Pearson, caliper, peak current 200kA, 0.001V/A

Maximum charge of 8As

Test the current waveform of W1, W4, W5A, and W5B

1539332471(1).jpg

THDP0100

The differential probe

American teck, 6kV differential mode, 100MHz frequency

Can be used to measure voltage signal of all waveforms

澳门新莆京7906not

A100 voltage attenuator

Damping ratio:100:1

The highest input 4000V

Frequency 400MHz, used for measuring W3, W2 high-frequency voltage waveform

澳门新莆京7906not

CS10 coaxial current attenuator

0.1V/A,frequency400MHz

Used to measure the current waveform of W3, W6.

澳门新莆京7906not

Cn-w3 high frequency capacitive coupler

Pulse coupling for W2, W3, and W6 waveforms

Meet the requirement of power supply for W2, W3, W6 pin injection test.

1539332476(1).jpg

HIP-W236

Handheld pins are injected into the probe

For insertion of W2, W3, and W6 waveforms,

The hand-held structure is designed to facilitate the surge injection of the pin of the product under test

Maximum working voltage is 10kV.

1539332487(1).jpg

Mobile test vehicle

With a weight of 500kg, it can be folded

Hydraulic lift, with cardan wheel, up to 01M

It can be used as a testing platform for heavy coupler and other desktop instruments such as LCT, LVT, etc

澳门新莆京7906not

D1548 test table

Fully solid wooden table design

Can choose 2mm aluminum or copper board desktop

Can choose reference to receive floor

With sizes of 0.8M*1.5M*0.8M, 1.2M*2.4M*0.8M, 1.5M*4.8M*0.8M, etc

Other sizes can also be customized

Note: due to the complexity of testing methods for the lightning indirect effect of airborne equipment, we can provide you with a professional configuration scheme from peak-pole electromagnetism to meet the test requirements, so as to ensure the smooth progress of your test.